The HeatWave SuperQuiet® SQ145 comes equipped with all standard features. The Patented ThermoLink® Titanium Heat Exchanger at its core makes this unit a power-house that’s built to last.
- Corrosion proof cabinet
- Scroll Compressor – for quiet operation
- Microprocessor Controls
- Off-Set Plumbing
Now you can control your heat pump right through your smartphone. Adjust your temperature setting in the PoolSync app.
*Additional purchase of PoolSync WiFi Controller required
AHRI’s globally recognized and industry respected heat pump pool heaters certification program provides outstanding value to equipment and component manufacturers, customers, and government regulators. AHRI Certified® products are subject to rigorous and continuous testing by a third-party laboratory under contract to AHRI. Only products certified by AHRI are listed in AHRI’s Directory of Certified Product Performance, a real-time database at web page. More information can be found online on the heat pump pool heaters Certification Program (web page), and the heat pump pool heaters contractors (web page).
California residents – Click here for Proposition 65 warning
Features
The only heat pump that allows you to maximize the potential savings of a variable speed pump is an AquaCal®, which utilizes our patented ThermoLink® Heat Exchanger technology with its unique flow characteristics.
• Patented hydraulic design adds only 2 PSI at 45 gpm, increasing compatibility with two-speed & variable speed pumps
• Saves money when using a variable speed pump by reducing the RPM needed to achieve the same flow rate
• Save money in a single speed pump application by reducing the run time needed to achieve the same turnover rate of the pool
Corrosion Proof Cabinet
• Louvered side panels protect evaporator coil while ensuring efficient air flow
• Rust and fade proof
• Impact resistant
• Built-in drain pan provides condensate management
Microprocessor Controlled with Digital Display
• Weather protected control with full text display provides easy-to-read menu options and unit status
• Ability to connect to most external controllers for heating and cooling mode
• Most common variable speed pumps can be programmed using the heat pump Smart Controller (HP9) or (HP11)
Additional Features
PoolSync® Ready
Adjust the mode to heat, cool or autotemp and set your temperature through the PoolSync App.
*Additional purchase of PoolSync WiFi Controller required
Brochures & Manuals
Specs
60 Hz | SQ145 | |||||
---|---|---|---|---|---|---|
BTUs (water temp/ambient air/relative humidity) |
||||||
80/80/80 | 121,000 | |||||
80/80/63 | 115,000 | |||||
80/50/63 | 75,000 | |||||
Coefficient of Performance (water temp/ambient air/relative humidity) |
||||||
80/80/80 | 7.1 | |||||
80/80/63 | 6.8 | |||||
80/50/63 | 4.2 | |||||
Refrigerant | R410A | |||||
Electrical | ||||||
Heat or Heat & Cool | H | |||||
kW Input | 5.1 | |||||
Voltage/Hz/Phase A – 208-230/60/1 B – 200-230/60/3 E – 380-415/60/3 G – 460/60/3 |
A, B & G | |||||
Minimum/Maximum Fuse Size | A – 60 B – 50 G – 20 |
|||||
Minimum Circuit Ampacity | A – 42.1 B – 31.0 G – 14.2 |
|||||
Water Flow *A Heater Bypass Kit is required when flow rates exceed the maximum |
||||||
Minimum/Maximum (gpm) | 30/70 | |||||
Physical | ||||||
Weight (lbs) | 305 | |||||
Length x Width x Height (in) | 34″ x 34″ x 44″ | |||||
Shipping | ||||||
Weight (lbs) | 345 | |||||
Length x Width x Height (in) | 37″ x 36″ x 51″ | |||||
Rated in accordance with AHRI standard 1160 water temp/ambient air/relative humidity |
Specs 60Hz
60 Hz | SQ145 | SQ225 | SQ120R | SQ166R | ||
---|---|---|---|---|---|---|
BTUs (water temp/ambient air/relative humidity) |
||||||
80/80/80 | 121,000 | 143,000 | 110,000 | 138,000 | ||
80/80/63 | 115,000 | 134,000 | 103,000 | 130,000 | ||
80/50/63 | 75,000 | 90,000 | 72,000 | 88,000 | ||
Coefficient of Performance (water temp/ambient air/relative humidity) |
||||||
80/80/80 | 7.1 | 6.5 | 5.5 | 6.1 | ||
80/80/63 | 6.8 | 6.1 | 5.3 | 5.8 | ||
80/50/63 | 4.2 | 4.0 | 4.0 | 4.2 | ||
Refrigerant | R410A | R410A | R410A | R410A | ||
Electrical | ||||||
Heat or Heat & Cool | H | H | H & C | H & C | ||
kW Input | 5.1 | 6.4 | 5.9 | 6.6 | ||
Voltage/Hz/Phase
|
A, B & G | A, B, E & G | A & B | A, B, E & G | ||
Maximum Fuse Size | A – 60 B – 50 G – 20 |
A – 60 B – 50 E – 30 G – 25 |
A – 60 B – 50 |
A – 60 B – 50 E – 30 G – 25 |
||
Minimum Circuit Ampacity | A – 42.1 B – 31.0 G – 14.2 |
A – 42.1 B – 33.3 E – 18.4 G – 16.2 |
A – 38.5 B – 31.0 |
A – 42.1 B – 33.3 E – 18.4 G – 16.2 |
||
Water Flow *A Heater Bypass Kit is required when flow rates exceed the maximum |
||||||
Minimum/Maximum (gpm) | 30/70 | 30/70 | 30/70 | 30/70 | ||
Physical | ||||||
Weight (lbs) | 305 | 315 | 273 | 310 | ||
Length x Width x Height (in) |
34″ x 34″ x 44″ | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ | ||
Shipping | ||||||
Weight (lbs) | 345 | 355 | 313 | 350 | ||
Length x Width x Height (in) | 37″ x 36″ x 51″ | 37″ x 36″ x 51″ | 37″ x 36″ x 51″ | 37″ x 36″ x 51″ | ||
Rated in accordance with AHRI standard 1160 water temp/ambient air/relative humidity |
Sylvester –
The AquaCal HeatWave heat pump has performed as advertised. It is super quiet. My installer commented that he had never seen a pool heat pump that was this quiet. He was very impressed.